Zabbix Agent cannot make counterpath: Unterschied zwischen den Versionen
Aus znilwiki
BLinz (Diskussion | Beiträge) (Die Seite wurde neu angelegt: „==Problem== Der Zabbix Agent liefert diverse Werte nicht, im Log des Agenten stehen Dinge wie:<br> 1756:20180705:170456.949 init_cpu_collector(): cannot make…“) |
(kein Unterschied)
|
Aktuelle Version vom 5. Juli 2018, 17:22 Uhr
Problem
Der Zabbix Agent liefert diverse Werte nicht, im Log des Agenten stehen Dinge wie:
1756:20180705:170456.949 init_cpu_collector(): cannot make counterpath for "\\": [0xC0000BBD] A required argument is missing or not correct. 3200:20180705:170456.949 check_counter_path(): cannot make counterpath for "\\": [0xC0000BBD] A required argument is missing or not correct. 3200:20180705:170456.949 active check "perf_counter["\238(_Total)\6"]" is not supported: Invalid performance counter path. 3200:20180705:170456.949 check_counter_path(): cannot make counterpath for "\\": [0xC0000BBD] A required argument is missing or not correct. 3200:20180705:170456.949 active check "perf_counter[\234(_Total)\1402]" is not supported: Invalid performance counter path. 3200:20180705:170456.949 check_counter_path(): cannot make counterpath for "\\": [0xC0000BBD] A required argument is missing or not correct. 3200:20180705:170456.949 active check "perf_counter[\234(_Total)\1404]" is not supported: Invalid performance counter path. 3200:20180705:170456.949 check_counter_path(): cannot make counterpath for "\\": [0xC0000BBD] A required argument is missing or not correct. 3200:20180705:170456.949 active check "perf_counter[\2\16]" is not supported: Invalid performance counter path. 3200:20180705:170456.949 check_counter_path(): cannot make counterpath for "\\": [0xC0000BBD] A required argument is missing or not correct. 3200:20180705:170456.949 active check "perf_counter[\2\18]" is not supported: Invalid performance counter path. 3200:20180705:170456.949 check_counter_path(): cannot make counterpath for "\\": [0xC0000BBD] A required argument is missing or not correct. 3200:20180705:170456.949 active check "perf_counter[\2\250]" is not supported: Invalid performance counter path. 3200:20180705:170458.763 active check "system.cpu.load[percpu,avg15]" is not supported: Collector is not started. 3200:20180705:170458.763 active check "system.cpu.load[percpu,avg1]" is not supported: Collector is not started. 3200:20180705:170458.763 active check "system.cpu.load[percpu,avg5]" is not supported: Collector is not started.
Ursache
Die normalerweise vorhanden Performancecounter von Windows sind beschädigt (Gelöscht etc).
Lösung
Eingabeaufforderung mit lokalen Administratorenrechten öffnen und
lodctr /R
ausführen.
Kommentare
Loading comments...